Welcome to Winner!
Global Site:简体中文
LASER PARTICLE SIZE ANALYZER FOR 30 YEARS
CHINA PARTICLE TESTING LEADING BRAND
SALES PHONE:0086-531-88876213
SEARCH
  • 关键字:
  • 商品分类:
  •  

basic attributes

Extended Attributes

  • Test Range:
  • Dispersion method:
  • Conditions of use:
  • Test samples:
RANKING
Your present location:Home >> Laser Particle Size Analyzer >> Wet Series >> Winner 2000B Semi-Auto Laser Particle Size Analyzer
  • Products Name: Winner 2000B Semi-Auto Laser Particle Size Analyzer
  • Products Number: 2000B
  • Add Time: 2011-02-17
  • Views : 12257

 
 
Winner20000B is a Laser Diffraction Particle Size Analyzer working with principle of Mie Scattering Theory to precisely determine the particle size distribution from 0.1 to 300 micrometer, with 3 gears of particle size distribution, with high sensitivity ring arrangement of photodetector greatly improve measurement accuracy and repeatability, Set ultrasonic agitation, ultrasonic dispersion, built-in circulation in one of dispersion system, completely solve the large particles deposited in the pipeline problem,It’s upgrade from JL9200  which is the 1st set of cement laser particle size analyzer in China, after practice during more than 10 years, It has become the most reliable and cost-effective laser diffraction particle size analyzer being widely use in test particle size distribution for industries.
 
 
 
Specifications:
 

Model Name

Winner2000B

Standard

ISO13320-1:1999, GB/T19077.1-2008, Q/JWN001-2009

Principle

MIE scattering principle

Measuring Range

0.1-40µm/0.6-120µm/1-300µm

Channels Number

32*3  PCS

Accuracy error

<1%   (CRM  D50 )

Repeatability error

<1%   (CRM D50 )

Light source

High performance He-Ne Laser (λ= 632.8nm,  P>2MW)

Lifetime>25000hour

 

Dispersion

 Method

Ultrasonic

Frequency:40KHz   Power:50W,   Time: ≥1S

Stir

Revolutions Speed: 0-300RPM (Adjustable)

Circulate

Rated Flow:8L/min    Rated Power:10W

Sample Pool

Volume:350mL

Micro-

Sample Pool

Volume: 10mL ( Available)

Operation Mode

Digital display control

Output parameter

D10,D50,D90,D100,S/V referent parameters

Optical Calibration System

Manual

Test Speed

<2mins per time

Outer dimension

L66*W32*H40cm

Net Weight

32Kg

Warranty

1 year

 
 
 
Main Features:
 
1) Adopt MIE Scattering Theory
2) Digtal display button operation
3)Full built-in integrated disperse system, contains Ultrasonic stirring, ultrasonic dispersion and   cycling system, prevent large particle sediment in the pipe.
3)Self-developed unconstrained free fitting technology, make particle analysis not restricted by any function, truly reflect particles distribution, ensure the good accuracy.
4)Adopt Patented converging light Fourier transform light path, efficiently improve resolution ratio of sub-micron particles.
5)Main& auxiliary detectors are fan-shaped, guarantee the effective capture of  all the scattered signal of particles. 
6) Three gears to offer precise size range for samples test.
 
 
                   ( Convergent Beam Fourier Transform Light Path)
 
Particle Size Analyzer (dispersion unit) Applications
 
Particle size distribution such as Median D50, D03, D06, D10, D16, D25, D75, D84, D90, D97,D98 in micron range.
Of Abrasives, Adhesives, Agrochemical• Barite, Batteries, Bentonite, Boron Carbide, Brucite, Bubble• Calcite, Calcium Carbonate, Carbon Black, Catalysts, Cement, Ceramics, Chemicals, Clay, Coal, Coatings, Corundum, Cosmetics• Diamond Powder, Dolomite, Diatomite• Emulsion, Environmental, Explosives• Ferrite, Flour, Fluorescent, Fluorite, Food & Beverage, Food Additive• Graphite, Grinding• Inks, Kaolin• Medicine, Metal Powder, Mica, Milling, Minerals• Oxides• Paints, Paper, Petrochemical, Pharmaceuticals, Pigments, Plaster, Plastics, Polymers• Quartz• Refractory, Resins• Silica, Slurries, Soil Sediments, Starch, Sulfur, Synthetics• Talc, Toners, Tourmaline• Wollastonite, Zeolite, Zirconium Silicate etc Hardware
 
 Software Function:
 
1, Analysis Mode
Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc. meet different demands of particle size statistic in different industries.
 
2,Statistic Method
Volume Distribution, Quantity Distribution 
 
3,Statistic Comparison
Statistic Several Testing Results to compare and analyze
Get difference by compare test result of different batches of samples, samples  before and after processing, and different time.
Have great practical significance to industrial raw materials quality control 
 
4,User-defined Analysis
Figure out percentage according to the particle size
Figure out particle size according to the percentage
Figure out percentage according to the particle size range
Meet demands of representation of particle test in different industries.
 
5,Test Report
Word, Excel,Photo( Bmp), Text etc.
 
6,Multiple language Support
Chinese&English (Others are available)
 
7,Intelligent Operation Mode
Automatically control water inflow, dispersion,test and analysis.
Better Repeatability after remove human-factor
 
 
Winner2000B Adopt Patents Technology:
 
  1. Optical bench design is protected by patent No.- ZL 2014 2 0378380.8, 
  2. MIE scattering principle application patent is protected by patent No.- ZL 2013 2 0812021.4.
  3. Wet circulation installation is protected by patent No.-ZL2010 2 0593526.2.
ⅠOperation interface:
  Run the software, access control systems interface, manually start the sample testing.
 
ⅡTesting analysis interface and report
 
After completed test, according to requirement to select records, Average result will be calculated, system generate analysis records form. When test in automatic mode, without data processing, the system automatically get analysis report and save the test records after a comprehensive analysis.
 
Messages
 
Message:
* Entered characters:0 Word
Less than or equal500Character
Your E-Mail:
*
example@mail.com
Phone number:
 
Please enter your Phone number
Verification code: