Winner2005B full automatic laser diffraction particle size analyzer,
with principle of Mie Scattering theory to precisely determine the particle size distribution from 0.1μm to 1000 μm. It enables you understand materials well, such as abrasives, adhesives, agrochemical,barite, Batteries, Bentonite, Boron Carbide, Brucite, Bubble,Calcite, Calcium Carbonate, Carbon Black, Catalysts, Cement, Ceramics, Chemicals, Clay, Coal, Coatings, Corundum, Cosmetics, Diamond Powder, Dolomite, Diatomite,Emulsion, Environmental, Explosives, Ferrite, Flour, Fluorescent, Fluorite, Food & Beverage, Food Additive,Graphite, Grinding, Inks, Kaolin, Medicine, Metal Powder, Mica, Milling, Minerals,Oxides,Paints, Paper, Petrochemical, Pharmaceuticals, Pigments, Plaster, Plastics, Polymers,Quartz,Refractory, Resins, Silica, slurry, Soil Sediments, Starch, Sulfur, Synthetics, Talc, Toners, Tourmaline,Wollastonite, Zeolite, Zirconium Silicate etc etc. Industry.
Main Specifications:
Model Name
|
Winner2005B
|
Standard
|
ISO13320-1:1999,GB/T19077.1-2008,Q/0100JWN001-2013
|
Principle
|
MIE scattering theory
|
Size range
|
0.1μm-1000μm
|
Detector Channels
|
66 pcs
|
Accuracy error
|
<1% (Deviation of D50 on national standard sample)
|
Repeatability error
|
<1% (Deviation of D50 on national standard sample)
|
Laser
|
He-Ne Laser λ= 632.8nm, p>2mW
|
Wet dispersion
|
Ultrasonic
|
Frequency:40KHz Power:35W, Time: ≥1S
|
Agitator
|
Revolutions Speed: 0-3000RPM (Adjustable)
|
Circulation
|
Rated Flow:8L/min Rated Power:10W
|
Sample pool
|
Volume: 350mL
|
Operation mode
|
Manual and Full automatic, 2 mode, freely choose
|
Optical alignment system
|
Full automatic optical path alignment system
|
Software function
|
Analysis mode
|
Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc.
|
Statistic Method
|
Volume Distribution, Quantity Distribution
|
Statistic Comparison
|
Several Testing Results of samples
Different batches of samples testing result,
Samples before and after processing,
Test result of samples in different time.
|
User-defined Analysis
|
Figure out percentage according to the particle size
Figure out particle size according to the percentage
Figure out percentage according to the particle size range
Meet demands of representation of particle test in different industries
|
Test Report
|
Word, Excel,Photo( Bmp), Text etc
|
Multiple-language Support
|
Multiple language Support
|
Intelligent operation
|
Automatically control water inflow, dispersion,test and analysis.Better Repeatability after remove human-factor
|
Testing speed
|
<2min/time
|
Outer dimension
|
L85cm*W39cm*H45cm
|
Net weight
|
40Kg
|
Main Features:
1)Unique stable converging fourier transform light path, measure range expanded from 0.1μm-1000μm.
2)Intelligent full automatic operation mode realize one key test, automatically draw water,ultrasonic dispersion, circulate and drain off water, so it not only could decrease workload, but also get better repeatability after remove human-factors errors.
3) Automatic optical light Calibration System is composed of precise four phase hybrid stepper motor, Its inching precision is reach to micron level, so light path is always in a good state..
4)Wet sample dispersion system: Full built-in setting mechanical stirring, ultrasonic dispersion, and circulation path in one, Big power-circulating pump and Optimization design of pipeline,effectively prevent large particle sediment.
5)Software support: Original Unconstrained free fitting technology make particle analysis not be restricted by any functions, truly reflect particles distribution.
Output parameters:(D50, D03, D06, D10, D16, D25, D75, D84, D90, D97,D98,set any value, S/V, D[3,2],D[4,3] )
Figure 1- Winner2005B laser particle size analyzer internal structure
Ⅱ test analysis view
After testing, if necessary, to select records generated an average result, the system analyzes the formation of the recording. When the automatic mode test, without data processing, forming and maintaining a comprehensive system automatically analyzed test records.
Patents Technology:
1)Optical bench design is protected by patent No.- ZL 2014 2 0378380.8,
2)Three dimensional-optical bench alignment system is protected by patent No.- ZL 2013 2 0835882.4.
3)MIE scattering principle application patent No.- ZL 2013 2 0812021.4.
4)Dual laser beam orthogonal application is protected by patent No.-ZL 2007 2 0025702.0
5)Wet circulation installation is protected by patent No.-ZL2010 2 0593526.2