Winner2009 large range laser particle sizer (wet)
Winer2009 is a wet large range laser particle sizer with a closely connected modular design and external dispersion system. The test range covers millimeter, micron, submicron and nanometer. The dual beam multi spectrum detection system and lateral light scattering test technology are used to effectively improve the test accuracy and performance of the instrument. It is mainly used for particle size testing and scientific research with wide particle distribution.
Keyword:
Category:
Wet laser particle sizer
E-mail:
Winner2009 large range laser particle sizer (wet)
Product introduction:
Winer2009 is a wet large range laser particle sizer with a closely connected modular design and external dispersion system. The test range covers millimeter, micron, submicron and nanometer. The dual beam multi spectrum detection system and lateral light scattering test technology are used to effectively improve the test accuracy and performance of the instrument. It is mainly used for particle size testing and scientific research with wide particle distribution.
Product features:
Distributed system with close connection modular design
The distributed system with close connection modular design is configured, and the high-power circulating pump is used to optimize the design of the pipeline, which improves the overall coordination of the product. The distributed system is independent of the test system, and the instrument maintenance is more convenient.
Automatic alignment of light path
The self-developed three-dimensional automatic alignment system (Patent No.: ZL. 2013 20835882.4) adopts a precision four phase hybrid stepping motor, with micro precision reaching the micron level, so that the optical path of the instrument is always in the alignment state, providing a basic guarantee for the accuracy and stability of the test results.
Double laser orthogonal optical path
Adopting the patent technology of convergent Fourier transform, the scattered light is not limited by the lens aperture; The double spectral plane optical path design is adopted, the measurement range is expanded to 2000 microns, the detection angle is 0.0155 degrees to 164 degrees, and the imported Fourier lens is adopted to ensure the stability and accuracy of particle measurement. The self-developed double laser orthogonal optical path, using the horizontally polarized light of the blue semiconductor assisted laser, can simultaneously accept the forward, lateral and back scattering light of nano particles, effectively improving the measurement accuracy of nano particle size.